{"title":"CAN","description":"","products":[{"product_id":"can-300-pro-communication-module","title":"CAN 300 PRO, Communication Module - 700-600-CAN12","description":"\u003cp\u003eThe CAN 300 PRO module of Systeme Helmholz GmbH for use in an S7-300* from Siemens permits connection of CAN stations with the programmable controller. The module can be slotted either in the central controller or in the expansion unit. The CAN 300 PRO module supports CAN 2.0A (11 Bit) and CAN 2.0B (29 Bit) frames with a freely selectable baud rate of 10 kbps to 1 Mbps. \u003cbr\u003eThe CAN 300 PRO module can send and receive CAN frames in Layer 2 operating mode. The data of the CANopen® slaves can be processed as a process image in CANopen® Master operating mode in the PLC. Applications as a CANopen® Slave is also possible. Application examples are provided for standard applications including motor control with CANopen®. Data handling blocks for the SAE J1939 protocol are also available.\u003cbr\u003eThe CAN 300 PRO module contains 16 freely settable timers. Each timer can trigger a freely programmable CAN telegram. That way, it is easy to implement the synchronous protocols in common use in drive and servo systems using the CAN 300 PRO module.\u003cbr\u003eThe DIP switch for setting the baud rate and the station address facilitate commissioning. An optional micro memory card stores the project so that the parameterization or the module is quickly replaced during servicing.\u003cbr\u003e6 LEDs indicate the operating status of the module. A USB interface is available for diagnostics and parameterization tasks. The CAN 300 PRO also works in the extended ambient temperature range of -25 °C to +60 °C.A USB cable is included.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e\u003cbr\u003eInformation about the parameterization software CANParam and about the data handling blocks for the PLC you will find under CAN Software. When first used, data handling blocks are required for the PLC.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eFeatures\u003cbr\u003e\u003c\/b\u003e• Layer 2, 11 Bit and 29 Bit (CAN 2.0 A\/B) \u003cbr\u003e• CANopen® Master on the module\u003cbr\u003e• DIP switch for adress + baud rate\u003cbr\u003e• Micro Memory Card for saving a project (optional)\u003cbr\u003e• USB Interface for parameterisation and diagnostics\u003cbr\u003e• Extensive CAN-Bus diagnostics\u003cbr\u003e• Can also be used as a CANopen® slave\u003cbr\u003e• Extended ambient temperature range\u003c\/p\u003e","brand":"Helmholz","offers":[{"title":"Default Title","offer_id":1025820060,"sku":"700-600-CAN12","price":1290.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0315\/8597\/products\/can300.jpg?v=1571708797"},{"product_id":"can-software","title":"CAN Software - 800-600-1AA11","description":"\u003cp\u003e\u003cb\u003eParameterization Tool CANParam\u003cbr\u003e\u003c\/b\u003eThe CAN modules are parameterized on the PC using the CANParam parameterization tool (contained in the 800-600-1AA11 software package). That makes setting the communication parameters easy. The parameterization of a module can be stored in a project on the PC.The CAN modules support both the protocol format CAN 2.0A (11 Bit) and CAN 2.0B (29 Bit). The CAN modules contain acceptance masks. These masks can be used to enable or disable various telegram IDs for reception. Express masks filter high-priority CAN telegrams so that they can be forwarded directly to the PLC.\u003cbr\u003eFor time-dependent events, such as the SYNC telegram in the case of CANopen®, up to 16 timers are available in the CAN modules up to a resolution of 1ms. Each timer can transmit any CAN telegram. The timers can be started, stopped, and changed from the PLC.\u003cbr\u003eThe timer 0 can also be used for synchronized transmission of CAN telegrams. It defines the time window in which all data will be transmitted synchronously.\u003cbr\u003eCAN telegrams can be transmitted or timers started via freely programmable scripts on certain events such as “Power ON” or “PLC Stop -\u0026gt; Run”. An integrated diagnostic function facilitates troubleshooting on commissioning of the module. For CAN 300 PRO’s CANopen® Master Function it’s both possible to define the masters properties as to parameterize the slaves existing on the CAN bus. In order to facilitate projection EDS-files can be read from CANopen® Slaves by CANParam Software.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eHandling blocks\u003cbr\u003e\u003c\/b\u003eThe CAN module is entered in the hardware configuration of the programming software as a CP- module (CAN 300, CAN 300 PRO) or an FM-module (CAN 400) and addressed in the STEP* 7 program via handling blocks. For the CAN modules, handling blocks are available for layer 2 communication and for CANopen® Master (DS301 V4). If CAN modules are to be used as a CANopen® Slave, data handling functions are available for the profiles DS401 (IO modules) and DS420 (Corrugator). Further profiles can be set up on request.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eFunction scope of layer 2 data handling function:\u003cbr\u003e\u003c\/b\u003e• Transmit CAN telegram\u003cbr\u003e• Read CAN telegram from the module\u003cbr\u003e• Transmit CAN telegram to a timer\u003cbr\u003e• Timer start\/stop\u003cbr\u003e• Module reset\u003cbr\u003e\u003cbr\u003eVarious CAN protocols in 11 Bit or 29 Bit mode can be implemented with the handling blocks for layer 2.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eFunction scope of the CANopen® Master data handling function:\u003cbr\u003e\u003c\/b\u003e• Read SDO\u003cbr\u003e• Transmit SDO\u003cbr\u003e• SDO segmented download\u003cbr\u003e• SDO segmented upload\u003cbr\u003e• Spontaneous receive (NMT,PDO, Emergency)\u003cbr\u003e• Transmit PDO\u003cbr\u003e• Request PDO\u003cbr\u003e• Nodeguarding\/Heartbeat\u003cbr\u003e• Network management\u003c\/p\u003e\n\u003cp\u003eApplication examples for controlling drives according to the DS402 profile are also supplied. Furthermore handling blocks are available to utilize CAN 300 PRO as DeviceNet Slave.\u003c\/p\u003e","brand":"Helmholz","offers":[{"title":"Default Title","offer_id":1025843044,"sku":"800-600-1AA11","price":395.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0315\/8597\/products\/cansw.jpg?v=1571708797"},{"product_id":"pn-can-gateway-profinet-canopen-700-670-pnc01","title":"PN\/CAN gateway, PROFINET\/CANopen - 700-670-PNC01","description":"\u003ch2 class=\"content--title\"\u003ePROFINET \/ CAN-Gateway CANopen Master\u003c\/h2\u003e\n\u003cdiv class=\"product--description\" itemprop=\"\"\u003e\n\u003cp\u003eThe PN\/CAN gateway CANopen represents a full-featured CANopen master. As a master, the gateway supports network management, SYNC telegrams, nodeguarding\/heartbeat for monitoring the nodes and LSS services. Up to 16 PDOs can be configured per CANopen slave. The parameterization of the CANopen nodes via SDO telegrams and the management of emergency messages is also possible.\u003c\/p\u003e\n\u003cp\u003eOn the PROFINET network, the PN\/CAN gateway is a PROFINET I\/O device and supports transmission rates of up to 100 Mbit full duplex; on the CAN bus, up to 1 Mbit\/s is supported.\u003c\/p\u003e\n\u003cp\u003eThe I\/O data of the CAN nodes are mapped transparently and freely configurable into the PROFINET network and can thus be processed directly in the PLC. The PN\/CAN gateway is integrated into the hardware configurator with a GSDML file and can be fully configured there. Further software tools for parameterization, or handling blocks for programming, are not necessary, which makes the use of the gateway uncomplicated.\u003c\/p\u003e\n\u003cp\u003eThe features MRP (media redundancy) as well as extensive diagnostic functions and an interface for online diagnostics complete the performance characteristics of the PN\/CAN gateway.\u003c\/p\u003e\n\u003cdiv class=\"product--features\"\u003e\n\u003cul\u003e\n\u003cli\u003eCANopen Master according to CANopen® protocol DSP 301\u003c\/li\u003e\n\u003cli\u003eUp to 126 CANopen slaves with up to 16 TPDOs \/ 16 RPDOs each\u003c\/li\u003e\n\u003cli\u003eUp to 1420 bytes input and 1420 bytes output data on PROFINET\u003c\/li\u003e\n\u003cli\u003eUp to 1 Mbit\/s CAN bit rate\u003c\/li\u003e\n\u003cli\u003eHeartbeat, Nodeguarding, SYNC\u003c\/li\u003e\n\u003cli\u003ePROFINET Conformance Class C\u003c\/li\u003e\n\u003cli\u003eMedia redundancy (MRP client)\u003c\/li\u003e\n\u003cli\u003eConfiguration via GSDML file\u003c\/li\u003e\n\u003cli\u003eNo handling blocks or parameterization software necessary\u003c\/li\u003e\n\u003cli\u003eUSB device interface for online diagnosis and firmware update\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Helmholz","offers":[{"title":"Default Title","offer_id":40580892098642,"sku":"700-670-PNC01","price":750.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0315\/8597\/files\/700-670-PNC01.png?v=1698264467"},{"product_id":"can-bus-connector-90-with-additional-connection-jack-700-690-1bb12","title":"CAN bus connector 90°, with additional connection jack - 700-690-1BB12","description":"\u003ch3 class=\"content--title\"\u003eCAN-Bus Connector \u003cspan\u003e90° with additional connection jack\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cdiv class=\"product--description\" itemprop=\"\"\u003e\n\u003cp\u003eHelmholz offers you the CAN bus connector for transmission rates up to 1 Mbps.\u003cbr\u003eThe CAN bus connector is plugged directly onto the CAN bus interface (SUB-D socket, 9-pin) of the CAN bus participants. The CAN bus cables are connected using 6-pin screw terminals.\u003cbr\u003eA slide switch is used to set whether the connector is to be used as a node or at the segment end.\u003cbr\u003eThe switch can also be operated in the installed condition. The setting is clearly visible.\u003cbr\u003eIn node setting (“OFF”), the connector must be operated when the incoming and outgoing bus are connected to each other. The terminating resistor is then ineffective.\u003cbr\u003eAs segment end (“ON”), the connector must be set on the first and last (outermost) participants of the segment respectively. In this case the terminating resistor is connected on the incoming bus, and the outgoing bus is disconnected.\u003cbr\u003eThe CAN connectors also work in the extended ambient temperature range of -25 °C to +85 °C.\u003c\/p\u003e\n\u003cp\u003eAdditional participants can be connected via the with additional connection jack.\u003c\/p\u003e\n\u003cdiv class=\"product--features\"\u003e\n\u003cul\u003e\n\u003cli\u003e24 V for participant supply\u003c\/li\u003e\n\u003cli\u003eMetalized housing\u003c\/li\u003e\n\u003cli\u003eNo parts that can be lost\u003c\/li\u003e\n\u003cli\u003eSmall size\u003c\/li\u003e\n\u003cli\u003eThe maximum ambient temperature for UL is +60 °C\u003c\/li\u003e\n\u003cli\u003eadditional connection jack\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003cbr\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Helmholz","offers":[{"title":"1+","offer_id":40580898095186,"sku":"700-690-1BB12","price":56.0,"currency_code":"USD","in_stock":true},{"title":"25+","offer_id":40580898127954,"sku":null,"price":53.0,"currency_code":"USD","in_stock":true},{"title":"50+","offer_id":40580898160722,"sku":null,"price":50.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0315\/8597\/files\/700-690-1BB12.png?v=1698264750"},{"product_id":"can-bus-connector-90-without-additional-connection-jack-700-690-1ba12","title":"CAN bus connector 90°, without additional connection jack  - 700-690-1BA12","description":"\u003ch3 class=\"content--title\" data-mce-fragment=\"1\"\u003eCAN-Bus Connector \u003cspan data-mce-fragment=\"1\"\u003e90°\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cdiv class=\"product--description\" data-mce-fragment=\"1\" itemprop=\"\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eHelmholz offers you the CAN bus connector for transmission rates up to 1 Mbps.\u003cbr data-mce-fragment=\"1\"\u003eThe CAN bus connector is plugged directly onto the CAN bus interface (SUB-D socket, 9-pin) of the CAN bus participants. The CAN bus cables are connected using 6-pin screw terminals.\u003cbr data-mce-fragment=\"1\"\u003eA slide switch is used to set whether the connector is to be used as a node or at the segment end.\u003cbr data-mce-fragment=\"1\"\u003eThe switch can also be operated in the installed condition. The setting is clearly visible.\u003cbr data-mce-fragment=\"1\"\u003eIn node setting (“OFF”), the connector must be operated when the incoming and outgoing bus are connected to each other. The terminating resistor is then ineffective.\u003cbr data-mce-fragment=\"1\"\u003eAs segment end (“ON”), the connector must be set on the first and last (outermost) participants of the segment respectively. In this case the terminating resistor is connected on the incoming bus, and the outgoing bus is disconnected.\u003cbr data-mce-fragment=\"1\"\u003eThe CAN connectors also work in the extended ambient temperature range of -25 °C to +85 °C.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product--features\" data-mce-fragment=\"1\"\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e24 V for participant supply\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eMetalized housing\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eNo parts that can be lost\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eSmall size\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eThe maximum ambient temperature for UL is +60 °C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003cdiv class=\"product--description\" itemprop=\"\"\u003e\n\u003cp\u003e \u003cbr\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Helmholz","offers":[{"title":"1+","offer_id":40580903731282,"sku":"700-690-1BA12","price":43.0,"currency_code":"USD","in_stock":true},{"title":"25+","offer_id":40580903764050,"sku":null,"price":41.0,"currency_code":"USD","in_stock":true},{"title":"50+","offer_id":40580903796818,"sku":null,"price":38.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0315\/8597\/files\/700-690-1BA12.png?v=1698264988"},{"product_id":"can-bus-connector-axial-straight-700-690-0ca12","title":"CAN bus connector, axial \/ straight - 700-690-0CA12","description":"\u003ch3 class=\"content--title\" data-mce-fragment=\"1\"\u003eCAN-Bus Connector \u003cspan data-mce-fragment=\"1\"\u003e180°\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cdiv class=\"product--description\" data-mce-fragment=\"1\" itemprop=\"\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eHelmholz offers you the CAN bus connector for transmission rates up to 1 Mbps.\u003cbr data-mce-fragment=\"1\"\u003eThe CAN bus connector is plugged directly onto the CAN bus interface (SUB-D socket, 9-pin) of the CAN bus participants. The CAN bus cables are connected using 6-pin screw terminals.\u003cbr data-mce-fragment=\"1\"\u003eA slide switch is used to set whether the connector is to be used as a node or at the segment end.\u003cbr data-mce-fragment=\"1\"\u003eThe switch can also be operated in the installed condition. The setting is clearly visible.\u003cbr data-mce-fragment=\"1\"\u003eIn node setting (“OFF”), the connector must be operated when the incoming and outgoing bus are connected to each other. The terminating resistor is then ineffective.\u003cbr data-mce-fragment=\"1\"\u003eAs segment end (“ON”), the connector must be set on the first and last (outermost) participants of the segment respectively. In this case the terminating resistor is connected on the incoming bus, and the outgoing bus is disconnected.\u003cbr data-mce-fragment=\"1\"\u003eThe CAN connectors work in the extended ambient temperature range of -25 °C to +85 °C.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product--features\" data-mce-fragment=\"1\"\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eMetalized housing\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eNo parts that can be lost\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eSmall size\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eThe maximum ambient temperature for UL is +60 °C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003cdiv class=\"product--description\" itemprop=\"\"\u003e\n\u003cp\u003e \u003cbr\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Helmholz","offers":[{"title":"1+","offer_id":40580910350418,"sku":"700-690-0CA12","price":50.0,"currency_code":"USD","in_stock":false},{"title":"25+","offer_id":40580910383186,"sku":null,"price":48.0,"currency_code":"USD","in_stock":true},{"title":"50+","offer_id":40580910415954,"sku":null,"price":45.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0315\/8597\/files\/700-690-0CA12.png?v=1698265203"}],"url":"https:\/\/pcc-test.myshopify.com\/collections\/can.oembed","provider":"Helmholz Sales online store for Helmholz parts in North America","version":"1.0","type":"link"}